Double Girder EOT Crane Design – Electrical Parts
Double Girder EOT Crane Power supply system
- Power supply: 220V – 660V, three phase current, three-wire
- Driving power supply: 220V – 660V,
- Control power supply: 24 VAC, 36 VAC, 220VAC
- Safety lighting power supply: 24 VAC, 36 VAC
- Maintenance Power Supply: 220V – 660V
Double Girder EOT Crane Electrical control system
- Main electrical components use Schneider.
- Emergency stop: Emergency stop button is arranged on the operating table and the general control panel of the electric room, when the operator has accident or the equipment failure, press the emergency stop button, the whole crane driving power and control power are cut off.
- Driver’s cabin using linkage control with zero self-locking, the linkage table must have clear power indicator and work indicator.
- Setting overload limiter, when lifting loads reach 90% of rated lifting capacity, alarming; reaching 105%, hoisting is prohibited.
- Control cabinet (panel) should have steady mounting base, to prevent vibration; control cabinet (panel) using front wiring; PVC wiring duct should be smooth, no glitches, and ground insulation skin, wire cable must be protected by the wire duct exit.
Double Girder EOT Crane Lighting system
- Driver’s Cabin lighting: 20W fluorescent light
- Under the main beam lighting: 2 halogen lamps
- Overhaul socket: set 220V – 660V, 36V socket in the following parts: Driver’s Cabin 220V – 660V, 36V 2pcs;
- Main beam 220V – 660V, 36V 3pcs
Double Girder EOT Crane Other parts
- Ensure maintenance space
- Cross traveling cable select pull resistant flexible cable, located terminal box at both ends of the cable; terminal box adopt bakelite board mounted brass screws as terminals.
- Wire cable laying on bridge frame, power, control, lighting and auxiliary circuits are all independent.
All double girder EOT crane using driver’s cabin and wireless remote control, single girder crane using ground pedant and wireless remote control.